PreferencesDialog
0
0
919
876
Preferences
-
-
0
0
180
16777215
true
false
1
-
Startup
-
Acquisition
-
Graphs
-
SCPI Server
-
0
0
16777215
16777215
2
-
-
When starting the application...
-
Autoconnect to the first device available
-
Set to...
-
-
-
Last used
StartupSweepGroup
-
Default values
StartupSweepGroup
-
Qt::Horizontal
40
20
-
Vector Network Analyzer
-
-
Type:
-
-
Frequency Sweep
-
Power Sweep
-
-
Frequency Sweep:
-
Start:
-
-
Stop:
-
-
Simulus level:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Power Sweep:
-
Start:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Stop:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Frequency:
-
-
-
Points:
-
1
4501
501
-
IF bandwitdh:
-
-
Averaging:
-
1
99
-
Signal Generator
-
Frequency:
-
-
Output level:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Spectrum Analyzer
-
Start:
-
-
Stop:
-
-
RBW:
-
-
Window:
-
-
None
-
Kaiser
-
Hann
-
Flat Top
-
Detector:
-
-
+Peak
-
-Peak
-
Sample
-
Normal
-
Average
-
Signal Identification:
-
-
Averaging:
-
1
99
-
Qt::Vertical
17
37
-
Qt::Horizontal
48
20
-
Vector Network Analyzer
-
<html><head/><body><p>If only S11/S21 or S22/S12 are enabled, faster sweeps are possible by only exciting one port. Checking this option forces the device to always excite both ports even when the measurements from one port will not be used.</p></body></html>
Always perform full 2-port measurement
-
<html><head/><body><p>Due to limited fractional divider settings, the source and 1.LO PLLs are not able to reach every frequency exactly. At some specific frequencies this causes the final IF to shift. At these frequencies there will be a positive or negative peak in the trace measurement that is not actually there.<br/><br/>Checking this option shifts the 2.LO for points where this could be an issue. This will remove the peaks but slows down the sweep slightly.</p></body></html>
Suppress invalid peaks
-
<html><head/><body><p>If enabled, the step attenuator setting will be changed during the sweep to keep the selected output power across frequency as accurate as possible.</p></body></html>
Adjust power level during sweep
-
Use harmonic mixing
-
Spectrum Analyzer
-
-
<html><head/><body><p>Normally, the spectrum analyzer mode tunes the LO for each point and measures the final IF only at one frequency. When this option is enabled, a DFT of the final IF is calculated instead which covers multiple frequencies with one measurement.</p><p>This can speed up the measurement at low RBWs significantly.</p></body></html>
Use DFT when RBW is below
-
-
Common
-
Averaging mode:
-
-
Mean
-
Median
-
Qt::Vertical
20
40
-
-
Show unit on graph axes
-
Colors
-
Background:
-
-
Axis:
-
-
Ticks
false
-
false
false
-
Tick lines:
-
-
Different background for every 2nd Y tick
true
-
Line Width:
-
0.100000000000000
-
Trace Domain Handling
-
<html><head/><body><p>A trace may change its output format/domain if certain settings are changed (e.g. from frequency to time domain when enabling TDR). Depending on the type of change, the graphs settings also have to be adjusted. Select the the behavior of the graphs when this happens:</p></body></html>
true
-
-
Remove changed trace from all unsupported graphs
-
Adjust graphs to support the changed trace (may remove other traces)
-
Adjust graph only if it contains no other traces
-
Marker Default Behavior
-
Show data on graphs
-
Show data in all available formats
-
Qt::Vertical
20
40
-
Qt::Horizontal
80
20
-
-
SCPI Control
-
Enable server
-
-
Port:
-
1
65535
-
Qt::Vertical
20
40
-
Qt::Horizontal
471
20
-
Qt::Horizontal
QDialogButtonBox::Ok|QDialogButtonBox::RestoreDefaults
false
SIUnitEdit
QLineEdit
CustomWidgets/siunitedit.h
ColorPickerButton
QPushButton
CustomWidgets/colorpickerbutton.h