PreferencesDialog
0
0
876
587
Preferences
-
-
0
0
180
16777215
true
false
1
-
Startup
-
Acquisition
-
Graphs
-
Marker
-
SCPI Server
-
true
0
-319
651
854
-
0
0
16777215
16777215
2
-
-
When starting the application...
-
Autoconnect to the first device available
-
Set to...
-
-
-
Last used
StartupSweepGroup
-
Default values
StartupSweepGroup
-
Setup file
StartupSweepGroup
-
Qt::Horizontal
40
20
-
2
-
The last used sweep settings (e.g. span, bandwidth,...) will be remembered. The graphs, traces and markers will not be remembered and the default configuration for them is used on startup.
true
-
Qt::Vertical
20
40
-
All settings (sweep settings as well as graphs, markers and traces) will be taken from the specified file. If the autosave option is checked, the current state of the GUI is stored in this file during shutdown as well.
true
-
-
File location:
-
-
0
0
20
16777215
...
-
Autosave to this file on shutdown
-
Qt::Vertical
20
545
-
These default values for the sweep settings will be used. The graphs, traces and markers will not be remembered and the default configuration for them is used on startup.
true
-
Vector Network Analyzer
-
-
Type:
-
-
Frequency Sweep
-
Power Sweep
-
-
Frequency Sweep:
-
Start:
-
-
Stop:
-
-
Simulus level:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Power Sweep:
-
Start:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Stop:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Frequency:
-
-
-
Points:
-
1
4501
501
-
IF bandwitdh:
-
-
Averaging:
-
1
99
-
Signal Generator
-
Frequency:
-
-
Output level:
-
dbm
-42.000000000000000
0.000000000000000
0.250000000000000
-
Spectrum Analyzer
-
Start:
-
-
Stop:
-
-
RBW:
-
-
Window:
-
-
None
-
Kaiser
-
Hann
-
Flat Top
-
Detector:
-
-
+Peak
-
-Peak
-
Sample
-
Normal
-
Average
-
Signal Identification:
-
-
Averaging:
-
1
99
-
Qt::Vertical
17
37
-
Vector Network Analyzer
-
<html><head/><body><p>If only S11/S21 or S22/S12 are enabled, faster sweeps are possible by only exciting one port. Checking this option forces the device to always excite both ports even when the measurements from one port will not be used.</p></body></html>
Always perform full 2-port measurement
-
<html><head/><body><p>Due to limited fractional divider settings, the source and 1.LO PLLs are not able to reach every frequency exactly. At some specific frequencies this causes the final IF to shift. At these frequencies there will be a positive or negative peak in the trace measurement that is not actually there.<br/><br/>Checking this option shifts the 2.LO for points where this could be an issue. This will remove the peaks but slows down the sweep slightly.</p></body></html>
Suppress invalid peaks
-
<html><head/><body><p>If enabled, the step attenuator setting will be changed during the sweep to keep the selected output power across frequency as accurate as possible.</p></body></html>
Adjust power level during sweep
-
Use harmonic mixing
-
Allow segmented sweep (increases maximum number of points)
-
Spectrum Analyzer
-
-
<html><head/><body><p>Normally, the spectrum analyzer mode tunes the LO for each point and measures the final IF only at one frequency. When this option is enabled, a DFT of the final IF is calculated instead which covers multiple frequencies with one measurement.</p><p>This can speed up the measurement at low RBWs significantly.</p></body></html>
Use DFT when RBW is below
-
-
Common
-
-
Averaging mode:
-
-
Mean
-
Median
-
IF frequencies
-
This section contains advanced system settings. It is recommended to leave them at default values unless you know what you are doing. Slight changes of the IF frequencies can be used to shift possible spikes to less problematic frequencies. Large changes of these frequencies may severely impact device performance.
true
-
-
IF 1:
-
<html><head/><body><p>Frequency of the first IF</p></body></html>
-
ADC prescaler:
-
<html><head/><body><p>ADC prescaler in FPGA. The ADC sample rate is determined by 102.4MHz/prescaler</p></body></html>
112
255
128
-
ADC sample rate:
-
false
-
Phase increment:
-
<html><head/><body><p>Phase increment per ADC sample. Together with the ADC sample rate this determines the frequency of the second IF</p></body></html>
1
4095
1280
-
IF 2:
-
false
-
Qt::Vertical
20
40
-
-
Show unit on graph axes
-
Size
-
Line Width:
-
0.100000000000000
-
Font (axes):
-
1
-
1
-
1
-
1
-
Font (trace names):
-
Font (marker data):
-
Font (cursor overlay):
-
Colors
-
Background:
-
-
Axis:
-
-
Ticks
false
-
false
false
-
Tick lines:
-
-
Different background for every 2nd Y tick
true
-
Trace Domain Handling
-
<html><head/><body><p>A trace may change its output format/domain if certain settings are changed (e.g. from frequency to time domain when enabling TDR). Depending on the type of change, the graphs settings also have to be adjusted. Select the the behavior of the graphs when this happens:</p></body></html>
true
-
-
Remove changed trace from all unsupported graphs
-
Adjust graphs to support the changed trace (may remove other traces)
-
Adjust graph only if it contains no other traces
-
Limit checking
-
Behavior:
-
-
Don't show any indication
-
PASS/FAIL text in graph corner
-
Overlay over whole graph on FAIL
-
Qt::Vertical
20
40
-
Qt::Horizontal
80
20
-
-
Default Behavior
-
Show data on graphs
-
Show data in all available formats
-
-
Positioning:
-
QComboBox::AdjustToContents
-
Snap to measurement points
-
Interpolate between points
-
Qt::Vertical
20
40
-
Qt::Horizontal
300
20
-
-
SCPI Control
-
Enable server
-
-
Port:
-
1
65535
-
Qt::Vertical
20
40
-
Qt::Horizontal
471
20
-
Qt::Horizontal
QDialogButtonBox::Ok|QDialogButtonBox::Open|QDialogButtonBox::RestoreDefaults|QDialogButtonBox::Save
false
ColorPickerButton
QPushButton
CustomWidgets/colorpickerbutton.h
SIUnitEdit
QLineEdit
CustomWidgets/siunitedit.h