PreferencesDialog 0 0 989 632 Preferences Qt::Horizontal 0 0 250 16777215 true false 1 Startup Acquisition Graphs Marker SCPI Server Debug Device Drivers 0 0 16777215 16777215 2 true 0 0 683 897 When starting the application... Autoconnect to the first device available Set to... Last used Default values Setup file Qt::Horizontal 40 20 2 The last used sweep settings (e.g. span, bandwidth,...) will be remembered. The graphs, traces and markers will not be remembered and the default configuration for them is used on startup. true Qt::Vertical 20 40 All settings (sweep settings as well as graphs, markers and traces) will be taken from the specified file. If the autosave option is checked, the current state of the GUI is stored in this file during shutdown as well. true File location: 0 0 20 16777215 ... Autosave to this file on shutdown Qt::Vertical 20 545 These default values for the sweep settings will be used. The graphs, traces and markers will not be remembered and the default configuration for them is used on startup. true Vector Network Analyzer Type: Frequency Sweep Power Sweep Frequency Sweep: Start: Stop: Simulus level: dbm -42.000000000000000 0.000000000000000 0.250000000000000 Power Sweep: Start: dbm -42.000000000000000 0.000000000000000 0.250000000000000 Stop: dbm -42.000000000000000 0.000000000000000 0.250000000000000 Frequency: Points: 1 4501 501 IF bandwitdh: Averaging: 1 99 Signal Generator Frequency: Output level: dbm -42.000000000000000 0.000000000000000 0.250000000000000 Spectrum Analyzer Start: Stop: RBW: Window: None Kaiser Hann Flat Top Detector: +Peak -Peak Sample Normal Average Averaging: 1 99 Qt::Vertical 17 37 true 0 0 697 563 Vector Network Analyzer <html><head/><body><p>If only S11/S21 or S22/S12 are enabled, faster sweeps are possible by only exciting one port. Checking this option forces the device to always excite both ports even when the measurements from one port will not be used.</p></body></html> Always create the stimulus signal at all ports Allow segmented sweep (increases maximum number of points) Common Averaging mode: Mean Median Full Span Behavior: Use maximum possible span as advertised by device Use manually defined full span Start frequency: Stop frequency: Use calibrated range as full span when calibrated Qt::Vertical 20 40 true 0 0 683 1058 Default Graphs For transmission measurements: For reflection measurements: XY Plot Polar Chart Waterfall Eye Diagram XY-Plot Smith Chart Polar Chart Waterfall Show unit on graph axes Size Line Width: 0.100000000000000 Font (axes): 1 1 1 1 Font (trace names): Font (marker data): Font (cursor overlay): Colors Background: Axis: Ticks false false false Tick lines: Different background for every 2nd Y tick true Sweep Indicator Show triangle of size 1 below X axis Qt::Horizontal 40 20 Show vertical line in graph Qt::Horizontal 40 20 Hide of displayed data after the sweep point Qt::Horizontal 40 20 Pan and Zoom Enable: Zoom factor: Trace Domain Handling <html><head/><body><p>A trace may change its output format/domain if certain settings are changed (e.g. from frequency to time domain when enabling TDR). Depending on the type of change, the graphs settings also have to be adjusted. Select the the behavior of the graphs when this happens:</p></body></html> true Remove changed trace from all unsupported graphs Adjust graphs to support the changed trace (may remove other traces) Adjust graph only if it contains no other traces Limit checking Behavior: Don't show any indication PASS/FAIL text in graph corner Overlay over whole graph on FAIL Qt::Vertical 20 40 true 0 0 683 605 Default Behavior Show data on graphs Standard formats dB dBm dBUv dB+Angle Real+Imaginary VSWR Impedance Resistance Capacitance Inductance Quality factor Special marker formats Select formats to be shown by default: P1dB Noise Phasenoise Insertion loss Cut-off frequency Center + Bandwidth TOI Average Tone Average Modulation Flatness Max. Delta Negative Max. Delta Positive Qt::Horizontal 40 20 Positioning: QComboBox::AdjustToContents Snap to measurement points Interpolate between points Sort order on graphs: X-Coordinate (Frequency/Time/Power) Number Creation timestamp Symbol Style: Filled triangle - Marker number inside Filled triangle - Marker number above Empty triangle - Marker number above Qt::Vertical 20 40 true 0 0 168 127 SCPI Control Enable server Port: 1 65535 Qt::Vertical 20 40 Qt::Horizontal 473 20 true 0 0 215 168 USB logging Maximum size: Trace saving Include datapoints Qt::Vertical 20 40 Qt::Horizontal 366 20 Qt::Horizontal QDialogButtonBox::Apply|QDialogButtonBox::Ok|QDialogButtonBox::Open|QDialogButtonBox::RestoreDefaults|QDialogButtonBox::Save false ColorPickerButton QPushButton
CustomWidgets/colorpickerbutton.h
SIUnitEdit QLineEdit
CustomWidgets/siunitedit.h