PML: try to fix pml working for a finite conductor waveguide
sigma > 1000 S/m is considered a conductor (not ideal solution) Signed-off-by: Thorsten Liebig <Thorsten.Liebig@gmx.de>pull/110/head
parent
cb63ab01c4
commit
568cdbdfac
|
@ -404,7 +404,9 @@ bool Operator_Ext_UPML::BuildExtension()
|
|||
CalcGradingKappa(n, pos,__Z0__ ,kappa_v ,kappa_i);
|
||||
nP = (n+1)%3;
|
||||
nPP = (n+2)%3;
|
||||
if ((kappa_v[0]+kappa_v[1]+kappa_v[2])!=0)
|
||||
// if eff_Mat[1] > 1e3 assume a metal and disable PML to continue a signal layer
|
||||
// sigma > 1000 S/m is "very lossy" already...
|
||||
if (((kappa_v[0]+kappa_v[1]+kappa_v[2])!=0) && (eff_Mat[1]<1e3))
|
||||
{
|
||||
//check if pos is on PEC
|
||||
if ( (m_Op->GetVV(n,pos[0],pos[1],pos[2]) + m_Op->GetVI(n,pos[0],pos[1],pos[2])) != 0 )
|
||||
|
|
Loading…