talise_fan_control: updated ip with new fan parameters

main
Arpadi 2019-08-15 18:25:47 +03:00 committed by István Csomortáni
parent aa5fdf903e
commit 63942a6b9b
2 changed files with 7 additions and 4 deletions

View File

@ -93,10 +93,10 @@ localparam PWM_ONTIME_75 = PWM_PERIOD * 3 / 4;
//tacho params
localparam TACHO_TOL_PERCENT = 25;
localparam TACHO_T25 = 3200000; // 32 ms
localparam TACHO_T50 = 1280000; // 12.8 ms
localparam TACHO_T75 = 720000; // 7.2 ms
localparam TACHO_T100 = 640000;
localparam TACHO_T25 = 1470000; // 14.7 ms
localparam TACHO_T50 = 820000; // 8.2 ms
localparam TACHO_T75 = 480000; // 4.8 ms
localparam TACHO_T100 = 340000; // 3.4 ms
localparam TACHO_T25_TOL = TACHO_T25 * TACHO_TOL_PERCENT / 100;
localparam TACHO_T50_TOL = TACHO_T50 * TACHO_TOL_PERCENT / 100;
localparam TACHO_T75_TOL = TACHO_T75 * TACHO_TOL_PERCENT / 100;

View File

@ -78,8 +78,11 @@ ad_connect sys_cpu_clk i2s_rx_dma/s_axis_aclk
ad_connect sys_cpu_resetn i2s_rx_dma/s_axi_aresetn
ad_connect sys_cpu_resetn i2s_rx_dma/m_dest_axi_aresetn
# fan control
ad_ip_instance axi_fan_control axi_fan_control_0
ad_ip_parameter axi_fan_control_0 CONFIG.ID 1
ad_ip_parameter axi_fan_control_0 CONFIG.PWM_FREQUENCY_HZ 1000
ad_connect axi_fan_tacho_i axi_fan_control_0/tacho
ad_connect axi_fan_pwm_o axi_fan_control_0/pwm