From 9b37e441f4f3a27903a31c9f696ac1fbb7af26c3 Mon Sep 17 00:00:00 2001 From: Lars-Peter Clausen Date: Wed, 19 Jul 2017 18:36:08 +0200 Subject: [PATCH] jesd204: jesd204_up_common: Rename clock monitor instance to i_clock_mon The generic Altera clock monitor constraints expect the instance to be called i_clock_mon. Adjust the code accordingly. Signed-off-by: Lars-Peter Clausen --- library/jesd204/axi_jesd204_common/jesd204_up_common.v | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/library/jesd204/axi_jesd204_common/jesd204_up_common.v b/library/jesd204/axi_jesd204_common/jesd204_up_common.v index 9b518d407..e2e57c987 100644 --- a/library/jesd204/axi_jesd204_common/jesd204_up_common.v +++ b/library/jesd204/axi_jesd204_common/jesd204_up_common.v @@ -283,7 +283,7 @@ end up_clock_mon #( .TOTAL_WIDTH(21) -) i_clk_mon ( +) i_clock_mon ( .up_rstn(~up_reset), .up_clk(up_clk), .up_d_count(clk_mon_count),