Make sure that the axi_adxcvr instances are configured with the same
transceiver type as the util_adxcvr.
This is necessary for software to be able to detect the transceiver type
and support dynamic reconfiguration.
It is also necessary for correct eye scan support in the axi_adxcvr block.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The external reference clock runs at 122.88 MHz by default. This means that
the QPLL feedback divider needs to be set to 80 so that the VCO is inside
the locking range (9.8 GHz - 16.375 GHz).
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>