This patch will fix the following critical warning, generated by Quartus:
"Critical Warning (18061): Ignored Power-Up Level option on the following
registers
Critical Warning (18010): Register ad_rst:i_core_rst_reg|rst_sync will power
up to High File: ad_rst.v Line: 50"
For a proper reset synchronization, the asynchronous reset signal should
be connected to the reset pins of the two synchronizer flop, and the
data input of the first flop should be connected to VCC.
In the first stage we're synchronizing just the reset de-assertion, avoiding
the scenario when different parts of the design are reseting at different time,
causing unwanted behaviours.
In the second stage we're synchronizing the reset assertion.
The module expects an ACTIVE_HIGH input reset signal, and provides an ACTIVE_LOW
(rstn) and an ACTIVE_HIGH (rst) synchronized reset output signal.
- remove reset logic
- add wait for dac valid logic
- rewrite sine concatenation on wires for different path width to
suppress warnings
- use computed atan LUT tables
The CORDIC has a selectable width range for phase and data of 8-24.
Regarding the width of phase and data, the wider they are the smaller
the precision loss when shifting but with the cost of more FPGA
utilization. The user must decide between precision and utilization.
The DDS_WD parameter is independent of CORDIC(CORDIC_DW) or
Polynomial(16bit), letting the user chose the output width.
Here we encounter two scenarios:
* DDS_DW < DDS data width - in this case, a fair rounding will be
implemented corresponding to the truncated bits
* DDS_DW > DDS data width - DDS out data left shift to get the
corresponding concatenation bits.
Update for the parametrized ad_mul module. This will scale
a selectable sine width in a multiplication module.
Rename the data and phase width parameters for legibility.
When the tool calculates the X value for different phase widths, we
get rounding errors for every width in the interval [8;24].
Depending on the width thess errors cause overflows or smaller amplitudes
of the sine waves.
The error is not linear nor proportional with the phase. To fix the issue
a simple aproximation was chosen.
Perform the shifting operation before addition/subtraction in a
rotation stage. In the previous method, the result of the arithmetic
operation was shifted and the outcome was presented to the next stage.
In this way, data connections will be reduced between pipeline stages
Add parameters:
- to select the sine generator (polynomial/CORDIC)
- to select the CORDIC data width(default 16)
Suppress the warnings generated when the DDS is disabled.
https://en.wikipedia.org/wiki/CORDIC
Configurable in/out data width (14,16,18,20);
The HDL implementation requires pipelines, resulting in a
data_width + 2 clock cycles delay between the phase input data and the
sine data. For this reason, a ddata (delay data) was propagated through
the pipeline stages to help in future use scenarios
The ADC DMA will never underflow and unsurprisingly the adc_dunf signal is
never used anywhere. It is very unlikely it will ever be used, so remove
it.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The DAC DMA will never overflow and unsurprisingly the dac_dovf signal is
never used anywhere. It is very unlikely it will ever be used, so remove
it.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Fix the following warnings that are generated by Quartus:
Warning (10230): Verilog HDL assignment warning at ad_sysref_gen.v(68): truncated value with size 32 to match size of target (8)
No functional changes.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Fix the following warnings that are generated by Quartus:
Warning (10036): Verilog HDL or VHDL warning at ad_datafmt.v(69): object "sign_s" assigned a value but never read
Move the sign_s and signext_s signals into the generate block in which
they are used.
No functional changes.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The DC filter implementation in library/common/dc_filter.v is Xilinx
specific as it uses the Xilinx DSP48 hard-macro. There is a matching Altera
specific implementation in library/altera/common/dc_filter.v.
Move the Xilinx specific implementation from the generic common folder to
the Xilinx specific common folder in library/xilinx/common/ since that is
where all other Xilinx specific common modules reside.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
In cases when a shallow FIFO is requested the synthesizer infers distributed RAM
instead of block RAMs. This can be an issue when the clocks of the FIFO are
asynchronous since a timing path is created though the LUTs which implement the
memory, resulting in timing failures. Ignoring timing through the path is not a
solution since would lead to metastability.
This does not happens with block RAMs.
The solution is to use the ad_mem (block RAM) in case of async clocks and letting
the synthesizer do it's job in case of sync clocks for optimal resource utilization.
This module upscale an n*sample_width data bus into a 16 or 32*n data
bus. The samples are right aligned and supports offset binary or two's
complement data format.
The up_rstn is driven by s_axi_resetn, which is generated by a
Processor System Reset module. (connected to port peripheral_aresetn)
Therefor using this reset signal as an asynchronous reset is redundant,
and a bad design practice at the same time. Asynchronous reset should be
used if it's inevitable.
The period_count should be updated once per clock cycle. This is not
enforced with the current implementation, which probably leads to
period_count being decremented on both m_axis_aclk edges.
A problem observed due to this is that the m_axis_tlast output is not
asserted or is asserted for a too short time for the consumer to
detect it.
Fix by letting the decrement (and thus the m_axis_tlast toggling)
happen only on the rising edge of the m_axis_aclk clock.
Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net>
At the moment the drain signal is always asserted when the controller is
enabled. This breaks backpressure and data is lost. The drain signal should
only be asserted when the controller gets disabled until the last beat of
the current DMA transfer.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The ADI transport layer peripherals expect the first octet to be in the
LSBs and the last octet to be in the MSBs. The Altera JESD204 core orders
the octets the other way around though, first octet in the MSBs and last
octet in the LSBS.
Currently this is handled by having each transport layer peripheral swap
the octets around when it is connected to the Altera JESD204 core.
Change this so that rather than having to do the data swizzling in every in
every transport layer peripheral perform it at the input/output of the link
layer peripheral inside the generated block.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>