Commit Graph

6 Commits (5ed2c0b599e9872d3c5f96e7b0bcfb90d7f45415)

Author SHA1 Message Date
Istvan Csomortani 9ba8c059ce ad_tdd_sync: Fix reset value of the pulse_counter 2015-11-13 18:31:24 +02:00
Istvan Csomortani fc0f4bc414 axi_ad9361: Delete the old sync generator from the core
+ Define two control signal for util_tdd_sync : tdd_sync_en and tdd_terminal_type
+ Delete to old ad_tdd_sync.v instances from the core
+ Update Make files
+ Update ad_tdd_control: add additional CDC logic for tdd_sync (the sync comes from another clock domain)
+ Update the ad_tdd_sync module: it's just a simple pulse generator, the pulse period is defined using a parameter, pulse width is fixed: 128 x clock cycle
+ Update TDD regmap: tdd sync period is no longer software defined
2015-11-11 11:06:19 +02:00
Istvan Csomortani c03983ca54 ad_tdd_sync/control: Update TDD logic
+ Redesign the TDD counter FSM
+ Make the sync logic independent from the tdd control
2015-09-25 19:11:23 +03:00
Istvan Csomortani 85ffc25ec5 ad_tdd_sync: Update the synchronization logic
The synchronization interface is a single bidirectional line. Output for Master, input for Slave.
The sync_period value is relative to frame length and the digital interface clock. The actual synchronization
period will be: sync_period * frame_length * fb_clock_cycle
2015-09-09 12:31:58 +03:00
Istvan Csomortani 10d9de39a1 axi_ad9361/tdd: Update the synchronization logic
The master will regenerate a sync pulse periodically. The period can be defined by software.
2015-08-19 12:21:23 +03:00
Istvan Csomortani d2c99acae8 fmcomms2/TDD: Update synchronization interface
Synchronization is done by a simple req/ack interface between a master and slave terminal.
2015-08-06 15:14:36 +03:00