The scripts generating the projects files typically only work correctly with
one specific version of Vivado. If a incorrect version is used the script
may fail at some point with a cryptic error message or may not fail but
create a bitstream that is not working as expected, e.g. unconnected
signals, etc. This patch adds a version check to adi_project_create that
will error out early on stating that the wrong version of Vivado was used
and which is the right version to use.
By default the required version will be the version that is required by the
common scripts. Individual projects can overwrite the required version by
setting the REQUIRED_VIVADO_VERSION variable to the required version or can
bypass the version check completely by setting the IGNORE_VERSION_CHECK
variable to 1.
Callers of the script can also disable the version check by setting the
ADI_IGNORE_VERSION_CHECK environment variable.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The scripts generating the projects files typically only work correctly with
one specific version of Vivado. If a incorrect version is used the script
may fail at some point with a cryptic error message or may not fail but
create a bitstream that is not working as expected, e.g. unconnected
signals, etc. This patch adds a version check to adi_project_create that
will error out early on stating that the wrong version of Vivado was used
and which is the right version to use.
By default the required version will be the version that is required by the
common scripts. Individual projects can overwrite the required version by
setting the REQUIRED_VIVADO_VERSION variable to the required version or can
bypass the version check completely by setting the IGNORE_VERSION_CHECK
variable to 1.
Callers of the script can also disable the version check by setting the
ADI_IGNORE_VERSION_CHECK environment variable.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
- increased the DMA FIFOs to 64
- added axi slices to the source and destination for DMAs
- for microblaze systems, increade the ad9643 dma data width at destination
- removed sys_fmc_dma_clk and used the sys_200m_clk instead for DMA data transfer
In 2014.2 tool version, the way how a definition file needs to be applied is different
The command "apply_bd_automation" should be used, instead setting property PCW_IMPORT_BOARD_PRESET
In non-project mode (PR design flow), after creating the static design the type of the board is set.
NOTE: the definition file for mitx must be installed accordingly in order to get this work
See link: http://zedboard.org/support/documentation/2056
Connect the SPARE_CLOCK_DUT pin to GPIO, this will be used to reset the AD9527.
The SPI interface for the clock chip is already integrated into the design.