If the streaming bit is set, after the trigger condition is met
data will be continuosly captured by the DMA. The streaming bit
must be set to 0 to reset triggering.
If the streaming bit is set, after the trigger condition is met,
data will be continuosly captured by the DMA. The streaming bit
must be set to 0 to reset triggering.
The DAQ3 does not use a 1-to-1 lane mapping for the DAC JESD204 link.
Provide the proper mapping when setting up the transceiver connections.
Without this the payload data will be mapped incorrectly and the
transmitted signals are scrambled.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
In non-streaming mode we want direction changes to be applied immediately.
The current code has a typo and checks the wrong signal. overwrite_data
holds the configured output value of the pin, whereas overwrite_enable
configures whether the pin is in streaming or manual mode.
For correct operation the later signal should be used to decide whether a
direction change should be applied. Otherwise the direction change will
only be applied if the output value of the pin is set to logic high.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
When using non-broadcast access to the GT DRP registers lane filtering is
done on both sides. The ready and data signals are filtered in the in the
axi_adxcvr module and the enable signal is filtered in the util_adxcvr
module. This works fine as long as both sides use the same transceiver IDs.
E.g. channel 0 of the axi_adxcvr module is connected to channel 0 of the
util_adxcvr module.
But this is not always the case. E.g. on the ADRV9371 platform there are
two RX axi_adxcvr modules (RX and RX_OS) connected to the same util_adxcvr.
The first axi_adxcvr uses lane 0 and 1 of the util_adxcvr, the second uses
lane 2 and 3.
Non-broadcast access for the first RX axi_adxcvr module works fine, but
always generates a timeout for the second axi_adxcvr module. This is
because lane 0/1 of the axi_adxcvr module is connected to lane 2/3 of the
util_adxcvr and when ID based filtering is done both can't match at the
same time.
To avoid this perform the filtering for all the signals in the axi_adxcvr
module. This makes sure that the same base ID is used.
This also removes the sel signal from the transceiver interfaces since it
is no longer used on the util_adxcvr side.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Always explicitly specify the signal width for constants to avoid warnings
about signal width mismatch.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The buffer delay should be 0 in the default configuration. The current
value of 0xb must have slipped in by accident.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Use a single standalone counter that counts the number of beats since the
release of the SYNC~ signal, rather than re-using the LMFC counter plus a
dedicated multi-frame counter.
This is slightly simpler in terms of logic and also easier for software to
interpret the data.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
There are currently two sysref related events. One the sysref captured
event which is generated when an external sysref edge has been observed.
The other is the sysref alignment error event which is generated when a
sysref edge is observed that has a different alignment from previously
observed sysref edges.
Capture those events in the register map. This is useful for error
diagnostic. The events are sticky and write-1-to-clear.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The internal LMFC offset signals are in beats, whereas the register map is
in octets. Add the proper alignment padding to the register map to
translate between the two.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
For SYSREF handling there are now three possible modes.
1) Disabled. In this mode the LMFC is generated internally and all external
SYSREF edges are ignored. This mode should be used for subclass 0 when no
external sysref is available.
2) Continuous SYSREF. An external SYSREF signal is required and the LMFC is
aligned to the SYSREF signal. The SYSREF signal is continuously monitored
and if a edge unaligned to the previous edges is detected the LMFC is
re-aligned to the new edge.
3) Oneshot SYSREF. Oneshot SYSREF mode is similar to continuous SYSREF mode
except only the first edge is captured and all further edges are ignored,
re-alignment will not happen.
Both in continuous and oneshot signal at least one external sysref edge is
required before an LMFC is generated. All events that require an LMFC will
be delayed until a SYSREF edge has been captured. This is done to avoid
accidental re-alignment.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Provide the correct lane mapping for the DAQ2 DAC lanes which do not follow
a 1-to-1 mapping between physical and logical lanes due to PCB layout
constraints.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Add a parameter to the ad_xcvrcon function that allows to provide a mapping
between logical and physical lanes. By default if no lane map is provided
the logial and physical lanes are mapped 1-to-1. If a lane map is provided
logical lane $n is mapped onto physical lane $lane_map[$n].
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
If the output pin is not defined as a clock, some of the Vivado IPI
propagation TCL will error out.
Signed-off-by: Matt Fornero <matt.fornero@mathworks.com>
If the output pin is not defined as a clock, some of the Vivado IPI
propagation TCL will error out.
Signed-off-by: Matt Fornero <matt.fornero@mathworks.com>