In some cases (GTX2) the transceiver may gate the out_clk when it is in
reset or misconfigured. This will stop the clock generators from getting
a clock prior removing the reset of the XCVR. The XCVR has a requirement
of running user clock while removing the reset. The correct sequence must be :
Enable device clocks (user clock)
Remove the reset from the XCVR
In some cases (GTX2) the transceiver may gate the out_clk when it is in
reset. This will stop the clock generators from getting a clock prior
removing the reset of the XCVR. The XCVR has a requirement of running
user clock while removing the reset. The correct sequence must be :
Enable device clocks (user clock)
Remove the reset from the XCVR
Reset CPACK from ADC TPL so during armed capture clear the cpack to avoid
capturing old samples.
Reset UNPACK with TPL to clear upack during armed transfers to avoid
sending old data.
Added the capability to set the JESD204 configuration values from a single
point in the code and to modify these default settings from the command
line for the Xilinx FPGAs in the project.
Signed-off-by: Dan Hotoleanu <dan.hotoleanu@analog.com>
Added the capability to set the JESD204 configuration values from a single
point in the code and to modify these default settings from the command
line for the Xilinx FPGAs in the project.
Signed-off-by: Dan Hotoleanu <dan.hotoleanu@analog.com>
Added the capability to set the JESD204 configuration values from a single
point in the code and to modify these default settings from the command
line for the Xilinx FPGAs in the project.
Signed-off-by: Dan Hotoleanu <dan.hotoleanu@analog.com>
Added the capability to set the JESD204 configuration values from a single
point in the code and to modify these default settings from the command
line.
Signed-off-by: Dan Hotoleanu <dan.hotoleanu@analog.com>
Add the capability to set the JESD204 configuration values from a single
point in the code and to modify these default settings from the command
line.
Signed-off-by: Dan Hotoleanu <dan.hotoleanu@analog.com>
- allow specifying the name of Axi Lite interface from the peripheral were to connect the control bus
- some DDR controllers have an Axi Lite control interface, this creates
a second address segment which causes issues, differentiate the memory
segment from control registers segment