.. _spi_engine interconnect:
|
|
|
|
SPI Engine Interconnect Module
|
|
================================================================================
|
|
|
|
.. hdl-component-diagram::
|
|
|
|
The SPI Engine Interconnect module allows connecting multiple
|
|
:ref:`spi_engine control-interface` masters to a single
|
|
:ref:`spi_engine control-interface` slave.
|
|
This enables multiple command stream generators to connect to a single
|
|
:ref:`spi_engine execution` and consequential give them access to the same SPI bus.
|
|
The interconnect modules take care of properly arbitrating between the different
|
|
command streams.
|
|
|
|
Combining multiple command stream generators in a design and connecting them to
|
|
a single execution module allows for the creation of flexible and efficient
|
|
designs using standard components.
|
|
|
|
Files
|
|
--------------------------------------------------------------------------------
|
|
|
|
.. list-table::
|
|
:widths: 25 75
|
|
:header-rows: 1
|
|
|
|
* - Name
|
|
- Description
|
|
* - :git-hdl:`library/spi_engine/spi_engine_interconnect/spi_engine_interconnect.v`
|
|
- Verilog source for the peripheral.
|
|
* - :git-hdl:`library/spi_engine/spi_engine_interconnect/spi_engine_interconnect_ip.tcl`
|
|
- TCL script to generate the Vivado IP-integrator project for the
|
|
peripheral.
|
|
|
|
|
|
Configuration Parameters
|
|
--------------------------------------------------------------------------------
|
|
|
|
.. hdl-parameters::
|
|
|
|
* - DATA_WIDTH
|
|
- Data width of the parallel SDI/SDO data interfaces.
|
|
* - NUM_OF_SDI
|
|
- Number of SDI lines on the physical SPI interface.
|
|
|
|
|
|
Signal and Interface Pins
|
|
--------------------------------------------------------------------------------
|
|
|
|
.. hdl-interfaces::
|
|
|
|
* - clk
|
|
- A signals of the module are synchronous to this clock.
|
|
* - resetn
|
|
- Synchronous active-low reset.
|
|
Resets the internal state of the module.
|
|
* - s0_ctrl
|
|
- :ref:`spi_engine control-interface` slave.
|
|
Connects to the first control interface master.
|
|
* - s1_ctrl
|
|
- :ref:`spi_engine control-interface` slave.
|
|
Connects to the second control interface master.
|
|
* - m_ctrl
|
|
- :ref:`spi_engine control-interface` master.
|
|
Connects to the control interface slave.
|
|
|
|
Theory of Operation
|
|
--------------------------------------------------------------------------------
|
|
|
|
The SPI Engine Interconnect module has multiple
|
|
:ref:`spi_engine control-interface` slave ports and a single
|
|
:ref:`spi_engine control-interface` master port.
|
|
It can be used to connect multiple command stream generators to a single command
|
|
execution engine. Arbitration between the streams is done on a priority
|
|
basis, streams with a lower index have higher priority. This means if commands
|
|
are present on two streams arbitration will be granted to the one with the lower
|
|
index. Once arbitration has been granted the port it was granted to stays in
|
|
control until it sends a SYNC command. When the interconnect module sees a SYNC
|
|
command arbitration will be re-evaluated after the SYNC command has been
|
|
completed. This makes sure that once a SPI transaction consisting of multiple
|
|
commands has been started it is able to complete without being interrupted by a
|
|
higher priority stream.
|