f232a36141
The paths from the HDMI interface registers to the IO pads are unconstrained. This means the P&R can in theory put the register anywhere which could lead to stability issues on the interface, depending on what else is in the fabric. To get predictable delays for the register to IO pad path place the register into the IOB section. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> |
||
---|---|---|
.. | ||
zc706_system_bd.tcl | ||
zc706_system_constr.xdc | ||
zc706_system_mig.prj | ||
zc706_system_mig_constr.xdc | ||
zc706_system_plddr3.tcl |